Home / Clinical Laboratory / Clinical Analyzer Calibrators and Reagents / Reagents / Reagent with Calibrator Kit / Reagent with Calibrator Kit Atellica® IM Cardiac Marker High-Sensitivity Troponin I For Atellica® IM Analyzer 500 Tests10997841
Picture of Reagent with Calibrator Kit Atellica® IM Cardiac Marker High-Sensitivity Troponin I For Atellica® IM Analyzer 500 Tests10997841

Reagent with Calibrator Kit Atellica® IM Cardiac Marker High-Sensitivity Troponin I For Atellica® IM Analyzer 500 Tests10997841

Reagent-with-Calibrator-Kit-Atellica®-IM-Cardiac-Marker-High-Sensitivity-Troponin-I-For-Atellica®-IM-Analyzer-500-Tests10997841

SKU #

#1123332

MPN #

10997841

Brand

Siemens

Stock

In Stock

Quantity

100

Features

REAGENT, ATELLICA IMMUNASSAY HS TROP (500TEST/KT)

$11,363.74 USD

Attribute Name Attribute Value
McKesson # 1123332
Manufacturer # 10997841
Brand Atellica® IM
Manufacturer Siemens
Application Reagent with Calibrator Kit
For Use With For Atellica® IM Analyzer
Form Ready-to-Use Liquid
Number of Tests 500 Tests
Product Dating McKesson Acceptable Dating: we will ship >= 90 days
Sample Type Human Serum / Plasma Sample
Storage Requirements Requires Refrigeration
Test Name High-Sensitivity Troponin I
Test Type Cardiac Marker
Type Chemiluminescent Immunoassay
UNSPSC Code 41116004

Similar Items

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

  • The Atellica® IM High‑Sensitivity Troponin I (TnIH) assay is for in vitro diagnostic use in the quantitative measurement of cardiac troponin I in human serum or plasma (lithium heparin) using the Atellica® IM Analyzer
  • Kit contents: 5 ReadyPack primary reagent packs containing Atellica IM TnIH Lite Reagent and Solid Phase, Atellica IM TnIH master curve and test definition, 2 vials Atellica IM TnIH CAL low calibrator, 2 vials Atellica IM TnIH CAL high calibrator, Atellica IM TnIH CAL calibrator lot-specific value sheet
  • The assay can be used to aid in the diagnosis of acute myocardial infarction (AMI)