Home / Respiratory / Anesthesia Systems / Refurbished Anesthesia Vaporizer / GE Datex Ohmeda® Refurbished Anesthesia VaporizerDAT-042
Picture of GE Datex Ohmeda® Refurbished Anesthesia VaporizerDAT-042

GE Datex Ohmeda® Refurbished Anesthesia VaporizerDAT-042

GE-Datex-Ohmeda®-Refurbished-Anesthesia-VaporizerDAT-042

SKU #

#1034329

MPN #

DAT-042

Brand

Soma Technology

Stock

In Stock

Quantity

100

Features

VAPORIZER, ANES SEVOFLURANE TEC 7 W/FILLER KEY

$3,548.18 USD

Attribute Name Attribute Value
McKesson # 1034329
Manufacturer # DAT-042
Brand GE Datex Ohmeda®
Manufacturer Soma Technology
Application Refurbished Anesthesia Vaporizer
Specifications 4.5 X 8.3 X 9.9 Inch, 225 mL Charged, 300 mL Charging, 75 mL Retention, 18 to 35°C Temperature, With Filler Key
UNSPSC Code 42271801

Similar Items

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

  • Refurbished in an ISO 13485 Certified FDA registered Facility in an ISO 13485 Certified FDA registered Facility
  • Two filling options: Easy-fil and funnel fill
  • The easy-fil filler is designed to simplify agent filling and help minimize agent leaks while filling
  • Large diameter control dial which incorporates fine graduations of 0.2% between 0 and 1% and 0.5% from 1 to 8%
  • Ergonomic agent dial release on the Tec 7 vaporizer allows either left or right-hand operation
  • Calibration: The dials of the Tec 7 vaporizers for enflurane, isoflurane and halothane are calibrated to 5% v/v in steps of 0.2% up to 1% and in steps of 0.5% from 1% to 5% at 21°C using O2 at 5 L/min as the carrier gas
  • Calibration of Sevoflurane: The dial of the Tec 7 vaporizer for sevoflurane is calibrated to 8% v/v, dial is marked in steps of 0.2% up to 1% v/v and in steps of 1% between 1% and 8%
  • Resistance to gas flow: Off: Isolated, no resistance from vaporizer, On: 5 L/min O2: 10 to 15 cm H2O at 21°C ±2°C
  • Accuracy: 5 L/min O2 @ 21°C ± 2°C: Vaporizer 5%: ±0.25% of delivered agent or ±15% of dial setting (whichever is greater), Vaporizer 8%: ±0.4% of delivered agent or ±15% of dial setting (whichever is greater), Flowrate: Vaporizers are designed to provide consistent output throughout the clinical flow range from 200 mL/min to 15 L/min