Home / Clinical Laboratory / Clinical Analyzer Calibrators and Reagents / Calibrators / Calibrator Kit / Calibrator Kit Access® IL-6 1 X 4 mL / 5 X 2.5 mL For Access IL-6 Assay on Access Family of Immunoassay SystemsA30944
Picture of Calibrator Kit Access® IL-6 1 X 4 mL / 5 X 2.5 mL For Access IL-6 Assay on Access Family of Immunoassay SystemsA30944

Calibrator Kit Access® IL-6 1 X 4 mL / 5 X 2.5 mL For Access IL-6 Assay on Access Family of Immunoassay SystemsA30944

Calibrator-Kit-Access®-IL-6-1-X-4-mL--5-X-2-5-mL-For-Access-IL-6-Assay-on-Access-Family-of-Immunoassay-SystemsA30944

SKU #

#1131784

MPN #

A30944

Brand

Beckman Coulter

Stock

In Stock

Quantity

100

Features

CALIBRATOR, ACCESS IL-6 CALS D/S

$893.98 USD

Attribute Name Attribute Value
McKesson # 1131784
Manufacturer # A30944
Brand Access®
Manufacturer Beckman Coulter
Application Calibrator Kit
Container Type Vial
For Use With For Access IL-6 Assay on Access Family of Immunoassay Systems
Levels 0, 2.5, 25, 250, 750 and 1,500 pg / mL
Test Name IL-6
Test Type Immunoassay
UNSPSC Code 41116004
Volume 1 X 4 mL / 5 X 2.5 mL

Similar Items

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

  • The Access IL-6 Immunoassay is only for use under the Food and Drug Administration’s Emergency Use: https://www.fda.gov/medical-devices/emergency-situations-medical-devices/emergency-use-authorizations
  • Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. §263a, to perform moderate or high complexity tests
  • This test has been authorized only to assist in identifying severe inflammatory response, when used as an aid in determining the risk of intubation with mechanical ventilation in confirmed COVID-19 patients
  • This test is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of medical devices under Section 564(b)(1) of the Federal Food, Drug and Cosmetic Act, 21 U.S.C § 360bbb- 3(b)(1), unless the authorization is terminated or revoked sooner
  • The Access IL-6 assay is an in vitro diagnostic test for the quantitative measurement of IL-6 (Interleukin 6) in human serum and plasma (heparin)
  • Normal IL-6 results do not preclude development of a severe inflammatory response, and IL-6 should not be used as the sole basis for patient management decision
  • Results must be combined with clinical observations, patient history, other laboratory parameters, and epidemiological information
  • S0 4 mL Vial, S1 - S5 2.5 mL Vial
  • For use with Access Family of Immunoassay Systems: Access 2, UniCel DxC 600i, UniCel DxI 600, UniCel DxI 800, UniCel DxC 880i, UniCel DxC 860i, UniCel DxC 680i, UniCel DxC 660i