Home / Sterilization / Sterilization Indicators / Sterilization Indicator Challenge Pack / Attest™ Super Rapid 5 Steam-Plus Sterilization Indicator Challenge Pack Steam 2 Inch41482VF
Picture of Attest™ Super Rapid 5 Steam-Plus Sterilization Indicator Challenge Pack Steam 2 Inch41482VF

Attest™ Super Rapid 5 Steam-Plus Sterilization Indicator Challenge Pack Steam 2 Inch41482VF

Attest™-Super-Rapid-5-Steam-Plus-Sterilization-Indicator-Challenge-Pack-Steam-2-Inch41482VF

SKU #

#1026077

MPN #

41482VF

Brand

3M

Stock

In Stock

Quantity

100

Features

INDICATOR, BIOLOGICAL ATTEST SUPR RAPID 5 STEAM (24/CS)

$358.94 USD

Attribute Name Attribute Value
McKesson # 1026077
Manufacturer # 41482VF
Brand Attest™ Super Rapid 5 Steam-Plus
Manufacturer 3M
Application Sterilization Indicator Challenge Pack
Class Class 1/5
Indicator Change Pink to Light Brown
Length 2 Inch
Sterilization Compatibility Steam
Temperature Range 270°F (132°C ) / 275°F (135°C)
Time To Results 24 Minute Read Time
UNSPSC Code 42281803

Similar Items

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

Underarm Crutches McKesson Aluminum Frame Tall Adult 350 lbs. Weight Capacity Push Button - Adjustment

One Size Fits Most White NonSterile Not Rated 8211

In Stock

PR/1 $9.76 USD

  • Each challenge pack contains a 3M™ Attest™ Super Rapid Readout Biological Indicator (1492V), a 3M™ Comply™ SteriGage™ Steam Chemical Integrator, and a record keeping sheet
  • Specifically designed for routinely challenging and conducting qualification testing of 270°F (132°C) and 275°F (135°C) dynamic‑air‑removal (pre‑vacuum) steam sterilization processes in healthcare facilities
  • Provides BI results in 24 minutes in 3M Attest 490/490H Auto-readers with software version 4.2.7 or greater
  • Dynamic-air-removal (Pre-vacuum and SFPP): 132˚C (270˚F) 4 min. 135˚C (275˚F) 3 min
  • Contains a 3M™ Attest ™ Super Rapid Readout Biological Indicator 1492V and a Type 5 chemical integrator
  • The biological indicator within the challenge pack contains viable organisms that provide a direct measure of lethality
  • Puts your instrument turnaround speed into overdrive